MBS-2 Installation
Pneumatic System
MBS-2 Location and Mounting
The MBS-2 can be located some distance from the relay valve. The air line
connecting the PCM to the relay valve should be 3 to 5 feet in length. This
allows some mounting flexibility, provides good ABS performance, and
complies with brake application and release timing requirements.
Mount the MBS-2 using two grade 8 bolts WNC part number BLT00650
(1/4-20 x 3-1/2") for 1M systems, BLT00732 (1/4-20 x 5-1/2") for 2M systems.
NOTE: Use the grade 8 bolts included with the MBS-2 installation kit.
The bolts must be inserted from the bracket side when installing 2M systems.
An optional mounting bracket (WNC part number 12S00475) is available from Wabash.
The MBS-2 may also be mounted directly to a crossmember by drilling two
mounting holes on 5-3/8" centers.
Figure 15, Typical MBS-2 Mounting
281UX030
Supply
Port
Delivery
Port
Exhaust
Port
Nut
Washer
Air Line
Tubing
ECM
PCM
PCM
Air Line
Tubing
Mounting Bracket
or Crossmember
Mounting
Bolt