Bendix™ BlindSpotter® Collision Warning SystemTroubleshooting GuideBendix™ BlindSpotter® Collision Warning SystemBW2860 (Formerly VOTS0032)September 2
Fault Isolation Procedures2-6Power-Up Sequence Test, continued Step C Procedure Condition Action1. Key off.2. Disconnect Operator Display Unit
Fault Isolation Procedures2-7Power-Up Sequence Test, continued Step D Procedure Condition Action1. Key off.2. Disconnect sensor harness J2.3.
Fault Isolation Procedures2-8Power-Up Sequence Test, continued Step E Procedure Condition Action1. Key off.2. Disconnect Operator Display Unit
Operator DisplayAudio TestSymptom Isolation Procedures3-1Operator Display Unit Audible Indictor(Buzzer) Not FunctioningOverviewThis symptom-driven te
3-2Symptom Isolation ProceduresOperator Display Unit Audible Indictor (Buzzer) Not Functioning Step A Procedure Condition Action Step B Procedure
3-3Operator DisplayAudio TestSymptom Isolation ProceduresOperator Display Unit Audible Indictor (Buzzer) Not Functioning, continued Step C Procedure
Symptom Isolation Procedures3-4Operator Display Unit Audible Indictor (Buzzer) Not Functioning, continued Step D Procedure Condition Action Step V
Symptom Isolation ProceduresSide SensorDetection Test3-5Side Sensor Not Detecting TargetsOverviewThis symptom driven test is performed when the s
3-6Symptom Isolation ProceduresSide Sensor Not Detecting Targets Step A Procedure Condition Action Step B Procedure Condition Action Step V P
Symptom Isolation ProceduresSide Sensor ContinuousDetection Test3-7Side Sensor Continuously DetectingTargetsOverviewThis symptom driven test is p
General InformationGeneral WarningsBefore starting a vehicle:1. Sit in the driver’s seat.2. Place the vehicle in neutral.3. Set the parking brake.4
3-8Symptom Isolation ProceduresSide Sensor Continuously Detecting Targets Step A Procedure Condition Action Step B Procedure Condition Action1.
Symptom Isolation Procedures3-9Side Sensor ContinuousDetection TestSide Sensor Continuously Detecting Targets, continued Step V Procedure Condition
Symptom Isolation Procedures3-10Side Sensor Continuously Detecting Targets, continuedThis page left blank intentionally.
A-1AppendixAppendixWiring DiagramsJ2 SODODU PWRODU GNDCOMMPWRGNDSIDE OBJECT DETECTION SENSORP2 SODJ1 ODUODU PWRODU GNDODU COMMTURN SIGNALOPERATORDISPL
A-2AppendixJ2J13214562134J1 O D UDISPLAYSENSORJ2 S O D72 INCHES240 INCHES1234563421PW RGN DCO M MOD U P W ROD U G N DRE DBL A C KWH I T EDK G R
A-3AppendixAppendixODU P12.0.702.32.11.02.02.8 BRACKET CANBE BENT± 15°10°FOUR #4 METAL SCREWS4 X 0 .125 THRUMTG. HOLESADHESIVE BACKING1.61.239" ±
A-4Appendix5.65.361.25 MTG. HOLE TOCLEAR CONNECTOR1.380.90.822.04 2.043.53P2 SODP2 SODNOTES:1) USE 3 #10-24 X 1 1/2" S.S.BUTTON HEAD CAP SCREWS F
AppendixAppendixThis page left blank intentionally.
Table of ContentsTable of ContentsSection 1: IntroductionDiagnostic Procedure ... 1-2Sect
901 Cleveland Street • Elyria, OH 44035 • 1-800-AIR-BRAKE • www.bendix.comBW2860 ©2011 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Br
1-2IntroductionDiagnostic ProcedureFollow the fl owchart below for all Bendix™ VORAD® system failures. Perform the tests and procedures as directed by
Fault Isolation Procedures2-1Electrical PretestElectrical PretestOverviewThe pretest verifi es the basic electrical inputs before testing indiv
Fault Isolation Procedures2-2Electrical Pretest Step A Procedure Condition Action1. Key off.2. Inspect starter/battery connections for integrity
Fault Isolation ProceduresElectrical Pretest2-3Electrical Pretest, continued Step C Procedure Condition Action1. Key off.2. Connect negative (-
Fault Isolation Procedures2-4Power-Up Sequence TestOverviewThe failure during the power-up self-check indicates a system failure.DetectionThe
Fault Isolation Procedures2-5Power-Up Sequence TestPower-Up Sequence Test Step A Procedure Condition Action Step B Procedure Condition Action1.
Comentarios a estos manuales