Vista de pagina 19
3-8
Symptom Isolation Procedures
Side Sensor Continuously Detecting Targets
Step A Procedure Condition Action
Step B Procedure Condition Action
1. Clear area around sensor
of objects.
2. Key on.
3. Allow Operator Display
Unit to go through self-test
and shows no targets
(yellow LED light should
be on).
1. Key on.
2. Remove Sensor from mounting
position.
3. Move Sensor out away from the
vehicle and place in an open area.
4. Key on.
5. Allow Operator Display
Unit to go through self-test
and shows no targets
(yellow LED light should
be on).
If both LED lights turn on
for .5 seconds – followed by
a red LED for fi ve (5) seconds –
followed by a continuous
yellow light
If both LED lights turn on
for .5 seconds, followed by
a continuous red light
If only red LED lights
If both LED lights turn on
for .5 seconds – followed by
a red LED for fi ve (5) seconds –
followed by a continuous
yellow light
If both LED lights turn on
for .5 seconds, followed by
a continuous red light
Go to Step V.
Go to Step B.
Replace Operator Display Unit.
Reposition sensor on vehicle
to allow clear detection zone.
Go to Step V.
Replace sensor. Go to Step V.