18 NEXIQ Brake-Link™ Bendix
®
& Eaton
®
ABS Applications
Chapter
2
• Establishing Connection
Figure 2.1
shows how to connect Brake-Link™ components for standard ABS
diagnostics.
Use the J560 PLC Cable Set in place of the Deutsch adapter if you plan to at-
tach to the tractor or trailer’s power line connector.
To connect Brake-Link™ components:
1 Attach the Power/Data Cable DB15 Connector to the data port (labelled
To Vehicle) on the Brake-Link™; tighten the thumbscrews.
Figure 2.1
Connectivity diagram for standard ABS
diagnostics.
Figure 2.2
J560 PLC Cable Set
Power/
Data Cable
6- or 9-Pin Deutsch
Note:
Where appli-
cable, substitute with
J560 PLC Cable Set
(Figure 2.2)
Quick
Disconnect