Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 101 of 126 April 19, 2010
COMPARTMENT LIGHTING
Each enclosed equipment compartment greater than 4 ft3 (0.1 m3) in volume and having an opening greater than 144 in.2
(92,900 mm2) shall have sufficient compartment lighting to provide a minimum of 2 fc (20 lx) at any location on the floor of
the compartment without any shelves, dividers, or equipment in the compartment.
Compartments such as ladder tunnels, pike pole storage tubes, or underbody compartments designed around the
volumetric requirements of specific equipment that can be removed without the use of article illumination shall not be
required to have compartment lighting.
All compartments shall be equipped with OnScene Nightstik LED lights with the following minimum light requirements;
17. Full Height Compartments, 63” Section (42 LED's)
18. Wheel well Compartments, 36” Section (24 LED's)
19. Rear Rescue Compartment, 63” Section (42 LED's)
20. Low Compartments, 18" Section (12 LED's), Vertical
21. Low Compartments, 36" Section (24 LED's), Horizontal
The OnScene Nightstik lights shall be rated at 100,000 hours of service and shall be provided with a 5 year free
replacement warranty.
ELECTRIC CORD REEL
Electric cord reel(s) shall be provided in exterior compartment as indicated in the numbered compartment list.
The 120 volt cord reel(s) shall be Hannay with electric rewind, equipped with fully enclosed 45 amp, three (3) conductor
collector rings.
The 12 volt reel rewind system shall be directly wired to the chassis battery system with heavy duty stranded copper wire,
with guarded finger type rewind button located within easy reach of the operator.
Each reel shall have a Hannay 4-way roller assembly to permit cable to feed directly off the reel and away from
compartment. Plastic roller assemblies are not acceptable.
The wiring from the generator system shall be through Carflex electrical weatherproof conduit, with stranded copper
wiring. The wiring shall terminate in a sealed conduit box at the reel with mechanical type connectors for quick removal of
wiring.
Cord Reel General Requirements
All permanently mounted cord reels shall be rated for continuous duty and installed to be accessible for removal, cord
access, maintenance, and servicing.
The power rewind cord reel spool area shall be visible to the operator during the rewind operation, or the reel spool shall
be encapsulated to prevent cord from spooling off the reel.
Rollers or guides shall be provided, where required, to prevent damage to the cord at reel spools or compartment
openings.
Rewind Provision
Power rewind type reels shall have the control in a position where the operator can observe the rewinding operation. If a
reel is in an enclosure or out of direct view, the cord entry point to the enclosure shall be visible to the operator of the reel
control.