Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 102 of 126 April 19, 2010
The rewind control or crank shall not be more than 72 in. (1830 mm) above the operator’s standing position. The rewind
control shall be marked with a label indicating its function and shall be guarded to prevent accidental operation.
Cord
The reel shall be designed to hold 110 percent of the capacity needed for the intended cord length.
The wire size shall be in accordance with NFPA 70, Table 400.5(A), but in no case shall it be smaller than 12AWG.
Electrical cord shall be Type SEOOW, Type SOOW, or Type STOOW.
A label that indicates the following information shall be provided in a visible location adjacent to any permanently
connected reel:
1. Current rating
2. Current type
3. Phase
4. Voltage
5. Total cord length
POWER DISTRIBUTION BOX
Where a power distribution box is hardwired to the end of a cord that is stored on a fixed cord reel or other fixed storage
means, the following requirements shall apply;
The remote power distribution box shall be listed for use in a wet location.
The distribution box shall be as follows:
1. Protected from corrosion
2. capable of being carried with a gloved hand
3. Designed to keep the exterior electrical components above 2 in. (51 mm) of standing water
Inlets, receptacles, circuit breakers, or GFCI devices shall not be mounted on the top surface of the horizontal plane.
Branch circuit breakers shall be installed in the remote power distribution box if the overcurrent device protecting the feed
cord to the box is too large to protect the wiring supplying the devices plugged onto the distribution box.
Remote power distribution boxes shall have a light on the box to indicate the power is on. The light shall be visible in a
360 degree plane from a minimum of 200 ft (60 m) in complete darkness. The light shall be mechanically protected to
prevent damage.
The hardwired portable cord connection to the box shall have strain relief and meet the intended usage requirements.
Vista de pagina 101