Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 25 of 126 April 19, 2010
APPARATUS WIRING PROVISION
An apparatus wiring panel shall be installed on the officer side bulkhead below the dash which shall include eight (8) open
circuits consisting of three (3) 20 amp, one (1) 30 amp, three (3) 10 amp, and one (1) 15 amp circuit, with relays and
breakers with trigger wires which shall be routed to the rocker switch panel.
MULTIPLEX DISPLAY
The multiplex electrical system shall include a Weldon Vista III Touchscreen display which shall be located on the left side
of the dash in the switch panel. The Touchscreen display shall feature a full color LCD screen. The display shall include a
message bar displaying the time of day, and important messages requiring acknowledgement by the user. There shall be
virtual controls for the auto climate control and on-board diagnostics. The display screen shall be video ready for back- up
cameras, thermal cameras, and DVD. A DIN type input connector ready for GPS interfacing shall be incorporated into the
back of the display.
The Touchscreen display shall measure approximately 6.25 inches wide x 3.38 inches in height. The display shall offer
varying fonts and background colors. The display shall be fully programmable to the needs of the customer and shall
offer virtually infinite flexibility for screen configuration options.
DATA RECORDING SYSTEM
The chassis shall have a Weldon Vehicle Data Recorder system installed. The system shall be designed to meet NFPA
1901 and shall be integrated with the Weldon Multiplex electrical system. The following information shall be recorded:
Vehicle Speed
Acceleration
Deceleration
Engine Speed
Engine Throttle Position
ABS Event
Seat Occupied Status
Seat Belt Status
Master Optical Warning Device Switch Position
Time
Date
Each portion of the data shall be recorded at the specified intervals and stored for the specified length of time to meet
NFPA 1901 guidelines and shall be retrievable by connecting a laptop computer to the VDR system.
POWER & GROUND STUD
A 40 amp battery direct power and ground stud shall be provided and installed in the electrical distribution panel. The
stud shall be size #10 and protected with a 40 amp circuit breaker.
AUXILIARY POWER & GROUND STUD
An auxiliary set of power and ground studs shall be provided and installed behind the electrical center cover with a 40
amp breaker. The studs shall be .375 inch diameter and capable of carrying up to a 40 amp load switched with the
master power switch.
EXTERIOR ELECTRICAL TERMINAL COATING
All terminals exposed to the elements will be sprayed with a yellow protective rubberized coating to prevent corrosion.