Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 126 of 126 April 19, 2010
The light tower shall have a full extension of 10' - 6" from mounted position and shall extend from nested position to full
upright in 20 seconds.
The overall size of the nested light tower shall be approximately 48" wide x 73" long x 15.1/4" high, and weigh
approximately 350 lbs.
A flashing warning light signal shall be provided indicating when a light tower is not in nested position as required by
NFPA 1901.
The operational envelope of the mast shall be automatically illuminated whenever the mast assembly is being raised,
lowered, or rotated as required by NFPA 1901.
The Command Light shall be covered by a One Year limited warranty from defects in materials and workmanship.
The light tower shall be mounted to roof of the custom cab which shall be reinforced as necessary to support weight of the
light tower.
LIGHT TOWER BRUSH GUARD
An 1/8" aluminum treadplate brush guard shall be provided on front and sides of specified light tower.
EQUIPMENT PAYLOAD WEIGHT ALLOWANCE
In compliance with NFPA 1901 standards, the special service vehicle shall be designed for an equipment loading
allowance of 6,000 lbs. of Windsor-Severance Fire Protection District provided loose equipment based on a 40,001 -
50,000 pound gross vehicle weight rating.
EQUIPMENT
The following equipment shall be furnished with the completed special service vehicle;
One (1) container of assorted stainless steel nuts, bolts, screws and washers used in the construction of the
apparatus shall be provided with the completed apparatus.
There shall be two (2) NFPA approved folding aluminum wheel chocks provided for 44" diameter tires that
together will hold the vehicle when loaded to its GVWR or GCWR, on a hard surface with a 20 % grade, with the
transmission in neutral, and the parking brake released.
- The wheel chock(s) shall be mounted behind rear wheels, below body on streetside.
Four (4) Streamlight LiteBox Vehicle Mounting Systems shall be provided. Each flashlight shall be orange in
color. Each flashlight shall have a 12 volt DC charger and vehicle mount kit. Each flashlight shall have a 20 watt
spotlight style bulb and reflector. The flashlights shall be wired to battery direct unless otherwise specified by the
customer.
- The flashlight(s) shall be mounted on the completed unit, evenly spaced across the rear surface of the engine
tunnel cover.
REMAINING NFPA MINOR EQUIPMENT BY PURCHASER
All other minor equipment not specified above, but required by NFPA 1901 before the unit is placed in service shall be
supplied and mounted by Windsor-Severance Fire Protection District.