Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 116 of 126 April 19, 2010
ZONE C - REAR WARNING LIGHTS (LOWER REAR CORNERS)
There shall be two (2) Whelen 600 series (6" x 4") red Linear Super-LED lights (60R02FRR) provided, one (1) each side.
Each light shall have a red lens and chrome flange.
The lights shall be switched at the Vista display in the cab.
LINE VOLTAGE ELECTRICAL SYSTEM
ONAN PTO GENERATOR
The apparatus shall be equipped with an Onan Protec PTO generator system with a capacity of 35,000 watts at 120/240
VAC, 291/145 amps., single phase. Current frequency shall be stable at 60 hertz.
The transmission’s PTO port and PTO, or the split shaft PTO, and all associated drive shaft components shall be
rated to support the continuous duty torque requirements of the generator’s continuous duty rating as stated on the power
source nameplate.
Where the generator is driven by the chassis engine and transmission through a split shaft PTO, the driving compartment
speedometer shall register when the generator drive system is engaged.
Where the generator is driven by the chassis engine and transmission through a split shaft PTO and a chassis
transmission retarder is furnished, it shall be automatically disengaged for generator operations.
The direct drive generator shall be mounted so that it does not change the ramp breakover angle, angle of departure, or
angle of approach as defined by other components, and it shall not extend into the ground clearance area.
The direct drive generator shall be mounted away from exhaust and muffler areas or provided with a heat shield
to reduce operating temperatures in the generator area.
GENERATOR ENGAGEMENT
A “Generator Engaged” indicator shall be provided in the driving compartment to indicate that the generator shift has been
successfully completed.
An “OK to Operate Generator” indicator shall be provided in the driving compartment to indicate that the generator is
engaged (if not always engaged), the transmission is in the proper gear (if required, automatic transmissions only), and
the parking brake is engaged (if applicable).
An interlock system shall be provided to prevent advancement of the engine speed in the driving compartment or
at any operator’s panel unless the parking brake is engaged, and the transmission is in neutral or the output of the
transmission is correctly connected to a pump or generator instead of the drive wheels.
WARRANTY PERIOD
Provided such goods are operated and maintained in accordance with Onan's written instructions, Onan warrants that the
Protec YDCR series PTO generators shall be free from defects in material and workmanship for a period of five (5) years
or one thousand (1,000) hours, whichever comes first, from the date of delivery to the first purchaser.
GENERATOR SPLASH GUARD
A powder coat painted splash cover shall be installed to reduce the amount of road spray on the frame mounted PTO
generator. A V-ring seal shall also be installed in the cover to provide additional protection against contaminates reaching
the generator front seals.