Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 70 of 126 April 19, 2010
OUTLETS AND CIRCUITS
The generator and or shore power shall supply the 120/240 volt electrical equipment and outlets outlined below. Proper
circuit protection shall be installed as noted:
There shall be one (1) 120 volt outlet(s) located inside this cabinet against the back wall unless noted otherwise.
- The outlet receptacle shall be 15 amp, straight-blade (NEMA 5-15R).
There shall be one (1) 120 volt outlet strip(s) approximately 4' long with straight blade household type outlets
provided with this outlet. The outlet strip shall be located along the back wall of the cabinet, justified to the inside
wall.
- Outlet(s) shall be powered by both the on-board generator and shore power system through a relay system.
FUEL FILL
There shall be one (1) Cast Products fuel fill door located in the streetside exterior wheel well panel, behind the rear axle.
The fill door shall have a spring-loaded hinged door and a permanent label with the text "DIESEL FUEL ONLY".
BODY DESIGN
The importance of public safety associated with emergency vehicles requires that the construction of this vehicle meet the
following specifications. These specifications are written to establish the minimum level of quality and design. All Bidders
shall be required to meet these minimum requirements.
It is the intent of these specifications to fully describe the requirements for a custom built emergency type vehicle. In
order to extend the expected service life of this vehicle, the body module shall be removable from the chassis frame and
be capable of being installed on a new chassis.
The sheet metal material requirements, including alloy and material thickness, throughout the specifications are
considered to be a minimum. Since such materials are available to all Manufacturers, the material specifications shall be
strictly adhered to.
The fabrication of the body shall be formed sheet metal. Formed components shall allow the Windsor-Severance Fire
Protection District to have the body repaired locally in the case where any object has struck the body and caused
damage. The use of proprietary extrusions will prevent the Windsor-Severance Fire Protection District from such repair
and shall NOT be used.
Following construction of the subframe, which supports the apparatus body, the sheet metal portion of the body shall be
built directly on the subframe. The joining of the subframe and body shall be of a welded integral construction.
The sheet metal fabrication of the body shall be performed using inert gas continuous feed welders only. The entire body
shall be welded construction. The use of pop rivets in any portion of structural construction may allow premature failure of
the body structure. Therefore, pop rivets shall NOT be used in the construction of the structural portions of the body. This
includes side body sheets, inner panels of compartment doors, and any other structural portions of the body.