SVI #774 Page 124 of 126 April 19, 2010
Wiring Schematics
An "As-Built" Wiring diagrams for line voltage systems shall be provided to include the following information;
1. Pictorial representations of circuit logic for all electrical components and wiring
2. Circuit identification
3. Connector pin identification
4. Zone location of electrical components
5. Safety interlocks
6. Alternatorbattery power distribution circuits
Input/output assignment sheets or equivalent circuit logic implemented in multiplexing systems
120/240 VAC SCENE LIGHTING
FRONT CAB-MOUNTED SCENE LIGHT(S)
Two (2) Fire Research Focus 1000 watt 240 volt (FCA800-M12) quartz floodlight(s) shall be provided on the front face of
the chassis cab. Each light shall be mounted in a Brow-style housing. Scene lights shall be provided with a lens or a
means for preventing damage from water spray and shall be listed for wet location usage.
Each light shall be wired directly to the electrical generator system with Carflex conduit and stranded copper wire. The
floodlights shall be protected with circuit breakers rated at the proper amperage and wire size.
There above lights shall be controlled by one (1) switch(es). The switch(es) shall be located in the cab within
reach of the Driver and/or Officer.
SIDE UPPER RECESSED SCENE LIGHTS
Four (4) Fire Research Focus, model FCA200-M12, recessed light(s) shall be installed. They shall be equally divided
between the curbside and streetside. The housing shall incorporate internal heat-dissipating fins and have cutout
dimensions not to exceed 2" deep by 4 1/4" high by 16 1/8" wide. The lamphead shall protrude no more than 1 1/2" from
the housing flange. Wiring shall extend from the bottom of the recessed housing.
The lamp head shall have one (1) quartz halogen 1000 watt 240 volt bulb. The bulb shall draw 4.2 amps and generate
22,000 lumens. The bulb shall be accessible through the front. The lamphead shall direct 50 percent of the light onto the
action area while providing 50 percent to illuminate the working area. Lamphead and housing shall be powder coated
white. The floodlight shall be UL listed as a scene light for fire service use.
Scene lights shall be provided with a lens or a means for preventing damage from water spray and shall be listed for wet
location usage.
There above lights shall be controlled by two (2) switch(es). The switch(es) shall be located in the cab within
reach of the Driver and/or Officer.