BENDIX M-12-M-12R ANTILOCK MODULATOR Especificaciones Pagina 81

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 80
Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 81 of 126 April 19, 2010
WALKWAY LIGHTS
There shall be Three (3) OnScene Solutions 9" LED Night Stik lights provided to illuminate the upper body walkway area.
The lights shall be activated when the parking brake is set.
Each light shall be mounted in a ball burnished cast aluminum housing to protect against damage from personnel or
equipment.
ROOF ACCESS STAIRWAY
The rear of the body shall be provided with a recessed center stairway with minimum 34" width. Stairs treads shall be 10"
minimum depth and formed from 3/16" NFPA compliant aluminum tread plate with uniformed riser height design. Stair
treads will be continuously welded into side walls, bolt-in treads will not be acceptable. Roll-out ladder design requiring
set-up time and 8 plus feet behind apparatus or vertical ladders that do not allow firefighter to safely ascend or descend
with equipment will not be acceptable.
STAIRWAY HANDRAILS
There shall be two (2) handrails provided, one (1) on each side wall of recessed center stairway providing three-points of
contact at all times for safer access to roof compartments. The handrails shall be angled for optimum use during ingress
or egress of the upper walkway area.
Handrails shall be NFPA compliant 1-1/4" extruded aluminum tubing with chrome plated end stanchions.
WALKWAY LIGHTS
There shall be Two (2) OnScene Solutions 9" LED Night Stik lights provided to illuminate the upper body walkway area.
The lights shall be activated when the parking brake is set.
Each light shall be mounted in a ball burnished cast aluminum housing to protect against damage from personnel or
equipment.
STEP COMPARTMENT - UPPER
There shall be one (1) upper compartment located below walkway area. The compartment shall have a horizontally
hinged door with a D-ring handle. The compartment shall be manufactured to prevent road debris, dirt and moisture from
entering the enclosure. The compartment shall be approximately 26" wide x 8" high x depth of equipment.
Each Compartment shall have an OnScene Solutions LED Night Stik that will be automatically activated when the door is
opened and wired to the NFPA required hazard warning light provided in the cab.
Devices to secure equipment, compartment dividers, or UHMW plastic angles, or sheeting will be used for storage of
specified equipment as required to prevent damage to equipment.
The compartment will be designed to store the following equipment:
One (1) 35' 3-section Windsor-Severance Fire Protection District supplied ladder.
One (1) 6' Windsor-Severance Fire Protection District supplied pike pole.
Vista de pagina 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 125 126

Comentarios a estos manuales

Sin comentarios