Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 55 of 126 April 19, 2010
BATTERY TRAY
The batteries shall be installed within two (2) steel battery trays located on the left side and right side of the chassis,
securely bolted to the frame rails. The battery trays shall be coated with the same material as the frame.
The battery trays shall include drain holes in the bottom for sufficient drainage of water. A durable, non-conducting,
interlocking mat made by Dri-Dek shall be installed in the bottom of the trays to allow for air flow and help prevent
moisture build up. The batteries shall be held in place by non-conducting phenolic resin hold down boards.
BATTERY CABLE
The starting system shall include cables which shall be protected by 275 degree F. minimum high temperature flame
retardant loom, sealed and encapsulated at the ends with heat shrink and sealant.
BATTERY JUMPER STUD
The starting system shall include battery jumper studs. These studs shall be located in the forward most portion of the
driver's side lower step. The studs shall allow the vehicle to be jump started, charged, or the cab to be raised in an
emergency in the event of battery failure.
ALTERNATOR
The starting system shall include a 270 amp Leece Neville 12 volt alternator. The alternator shall include a self-excited
integral regulator.
BATTERY CONDITIONER
A Kussmaul 1200 battery conditioner shall be supplied. The battery conditioner shall be mounted in the cab behind the
driver's seat.
BATTERY CONDITIONER DISPLAY
A Kussmaul battery conditioner display shall be supplied. The battery conditioner display shall be mounted in the cab,
viewable through the cab mid side window behind the left front door.
ELECTRICAL INLET
A Kussmaul 20 amp electrical receptacle shall be supplied.
A single item or an addition of multiple items must not exceed the rating of the electric inlet that it’s connected to.
Amp Draw Reference List:
Kussmaul 1000 Charger - 3.5 Amps
Kussmaul 1200 Charger - 10 Amps
Kussmaul 35/10 Charger - 10 Amps
1000W Engine Heater - 8.33 Amps
1500W Engine Heater - 12.5 Amps
120V Air Compressor - 4.2 Amps
ELECTRICAL INLET LOCATION
An electrical inlet shall be installed in the left hand side lower front step in the rear position.