Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 97 of 126 April 19, 2010
ROOF ACCESS STAIRWAY
The rear of the body shall be provided with a recessed center stairway with minimum 34" width. Stairs treads shall be 10"
minimum depth and formed from 3/16" NFPA compliant aluminum tread plate with uniformed riser height design. Roll-out
ladder design requiring set-up time and 8 plus feet behind apparatus or vertical ladders that do not allow firefighter to
safely ascend or descend with equipment will not be acceptable.
STAIRWAY HANDRAILS
There shall be two (2) handrails provided, one (1) on each side wall of recessed center stairway providing three-points of
contact at all times for safer access to roof compartments. The handrails shall be angled for optimum use during ingress
or egress of the upper walkway area.
Handrails shall be NFPA compliant 1-1/4" extruded aluminum tubing with chrome plated end stanchions.
PLASTIC FLOOR AND SHELF TILE
All compartment floors, shelves, and trays shall be covered with Dri-Dek plastic interlocking grating.
The plastic floor tile shall be black.
The plastic edge trim shall be black.
ROPE TIE-OFF OR PORTABLE WINCH RECEIVERS
The completed unit shall have an integrated receiver system for use with rope rescue accessories and/or electric winch
components. Each receiver shall have the following load rating:
STRAIGHT PULL
Rope Tie Off:
SAFETY FACTOR
600 LBS.
15:1
Winch:
1,000 LBS
4:1
The following items shall be provided to accomplish rope rescue or portable winch operations:
Two (2) rope tie off anchor accessories shall be provided with the completed vehicle. Each accessory shall
include a push button detent pin to lock it in place. The tie off accessories shall have an eyelet for use with a rope
rescue carabineer. A mounting bracket shall be provided to store each rope tie off accessory in a body
compartment, location shall be determined by the Windsor-Severance Fire Protection District.
There shall be one (1) receiver tube(s) located at the front bumper for use with a portable winch or tie-off point
accessory.
- There shall be one (1) rubber cover / plug for the receiver.
There shall be one (1) receiver tube(s) located on the streetside of the body in the forward portion of the wheel
well panel for use with a portable winch or tie-off point accessory.
- There shall be one (1) rubber cover / plug for the receiver.
There shall be one (1) receiver tube(s) located on the curbside of the body in the forward portion of the wheel well
panel for use with a portable winch or tie-off point accessory.
- There shall be one (1) rubber cover / plug for the receiver.