Vista de pagina 38
Windsor-Severence Fire Protection District
Heavy Rescue
Production Specification
SVI #774 Page 39 of 126 April 19, 2010
AIR SUPPLY LINES
A dual air system plumbed with color coded reinforced nylon tubing air lines shall be installed on the chassis. The primary
(rear) brake line shall be green, the secondary (front) brake line red, the parking brake line orange and the auxiliary
(outlet) will be blue.
Brass compression type fittings shall be used on the nylon tubing. All drop hoses shall include fiber reinforced neoprene
covered hoses.
AIR INLET CONNECTION
An air connection for the shoreline air inlet shall be supplied.
AIR INLET LOCATION
The air inlet shall be installed in the left hand side lower front step in the forward position.
PLUMBING AIR INLET CONNECTION
The cab mounted air inlet connector shall be plumbed to the air system with a check valve to prevent air from escaping
through the inlet connector.
AIR INLET/ OUTLET FITTING TYPE
The air connector supplied shall be a 0.25 inch size Tru-Flate Interchange style manual connection which is compatible
with Milton ‘T’ style, Myers 0.25 inch Automotive style and Parker 0.25 inch 10 Series connectors.
WHEELBASE
The chassis wheelbase shall be 238.00 inches.
REAR OVERHANG
The chassis rear overhang shall be 86.00 inches.